XDS35i
詳細介紹:XDS35i
|
| XDS35i | XDS35i Enhanced |
Peak pumping speed | m3h-1(cfm) | 35 (21) | |
Ultimate vacuum (1) | mbar (Torr) | 0.01 (0.008) | 0.03 (0.02) |
Ultimate vacuum with gas ballast 1 | mbar (Torr) | 0.02 (0.015) | 0.04 (0.03) |
Ultimate vacuum with gas ballast 2 | mbar (Torr) | < 10 (7.5) | |
Max inlet pressure for water vapour | mbar (Torr) | 35 (23) | |
Water vapour handling capacity GBII | gh-1 | 240 | |
Maximum continuous inlet pressure | mbar a (Torr a) | 40 (30)(2) | 1000 (760) * |
Maximum gas ballast/purge pressure | bar gauge (psig) | 0.5 (7) | |
Motor data | |||
Supply voltage | V | 100-120/200-240 (+/- 10%) | |
Supply frequency | Hz | 50/60 | |
Nominal rotation speed | rpm | 1750 | |
Power at ultimate | W | 440 | |
Motor power | W | 520 | |
Power connector | IEC | EN60320 C19 | |
Recommended fuse, 230 V (115 V) | A | 16 (3) (15) | |
Physical data | |||
Weight | kg (lb) | 48 (105) | |
Inlet connection |
| NW40 | |
Exhaust connection |
| NW25 | |
Noise level at ultimate | dB(A) | 57 | |
Vibration at inlet flange | mms-1 (rms) | < 4.5 | |
Leak tightness (static) | mbar ls-1 | < 1 x 10-6 | |
Operating temperature range | °C (°F) | 5 to 40 (41 to 104) |
* Use at higher inlet pressure speeds up tip seal wear
(1) measured as total pressure
(2) These pumps are designed to pump down from atmosphericpressure, but prolonged operation at inlet pressures higher than specified mayreduce bearing life.
(3) for UK 240 V use 13 A fuse
XDS35i 100-120/200-230V 1 ph 50/60Hz set to 230V;P/N:A73001983
XDS35i NGB 100-120/200-230V 1 ph 50/60Hz set to 230V;P/N:A73005983
XDS35iC 100-120/200-230V 1 ph 50/60 Hz set to 230V;P/N:A73006983
XDS35iE 100-120/200-230V 1PH 50/60Hz Enhanced;P/N:A73003983
XDS35iE NGB 100-120/200-230V 50/60Hz Enhanced;P/N:A73007983
XDS35iCE 100-120/200-230V 1PH 50/60Hz Enhanced;P/N:A73008983
-------相關配件連結--------------
EDWARDS XDS 35I TIP SEALS & EXHAUST KIT